Product Details
+
Server Technology PRO2 Switched PDU C2W48TE-5CAE2M99 - Power distribution unit (rack-mountable) - AC 415 V - 17.3 kW - RS-232, Ethernet 10/100/1000 - input: NEMA L22-30P - output connectors: 48 (30 x IEC 60320 C13, 18 x IEC 60320 Cx)
- Network monitoring
Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more. - Hot swappable
Network access is ensured when power is lost to the Primary unit with backup power provided by the primary link unit. - Multi link expansion
Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card. - Environmental monitoring
Primary and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications. - Input current monitor
Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets. - Per-Inlet Power Sensing
Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy. - Branch current monitoring
PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit. - Branch circuit protection
This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses. - Outlet control
On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles. - Alternating-phase outlets
3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow. - High retention locking outlets
Receptacles have high retention and are compatible with P-Lock type power cords. - High temperature rating
This product has been tested and approved for safe and reliable operation in 60 °C data center environments. - Flexible mounting
Includes standard button mounts along with provisions for custom mounting brackets.
- Network monitoring
- Hot swappable
- Multi link expansion
- Environmental monitoring
- Input current monitor
- Per-Inlet Power Sensing
- Branch current monitoring
- Branch circuit protection
- Outlet control
- Alternating-phase outlets
- High retention locking outlets
- High temperature rating
- Flexible mounting